PRODUCTS:
We make all type of batteries as per your requirement.
1. AUTOMOTIVE BATTERIES
2. TUBULAR BATTERIES
Initial Charging Instruction
Initial Charging instruction Initial Charging decides the life of
the battery. Take utmost care to charge the battery initially strictly
as per manufacturer's charging instructions.
1. Filling in Specific Gravity 1.220 + 0.005 at 270C
2. Rest Period 12 hrs.
3. Initial charging Current 5 amps to 7 amps for automotive batteries
up to 10amps for
stationery tubular batteries.
4. Conditions of fully charged
a) 3 consecutive hourly readings of Specific
Gravity and voltage become constant.
b) Top of charging voltage will be around
15.5V - 16.2V
c) All cell should gas freely
5. Specific Gravity at fully charged condition must be (recommended to be) 1.240 + 0.005 at
270C
for stationary tubular batteries and 1.230 + 0.005 at 270C for automotive
batteries.
Note:
Ensure that the temperature of the electrolyte during charging does
not exceeds, 550C. if it exceeds, reduce the charging
current or discontinue charging and resume charging when the temperature
come down to 450C.
Normal Recharging Instruction
Charging at limit current up to 13.8V
Installation
1. Wooden or Rubber matting should be used for placing the
battery.
2. 12V or 24V requirement 1 or 2 Batteries may be connected in series.
3. Higher current requirement series-parallel connection may be
used.
This catalog is issued to provide outline information only and is not deemed to form part of an
offer of contract. Our Policy is one of continued improvement and we reserve the right to change details without prior notice.
|